Why Humidification Systems For Server Rooms Need Maintenance

 

Server rooms can become very dry with air conditioning systems running all the time taking condensate out of the air and removing moister from the area. Low humidity can cause static build up on server room equipment and this is obviously damaging to sensitive equipment. If the server room is occupied by personnel the dry air can cause breathing problems, dry skin or itchy eyes. This is why professional server room air conditioning installations use a humidification unit such as a Vapac system. The Vapac humidifiers have been on the market for years and are a simple and effective way of humidifying. Its uses a heater bottle with internal electrodes to heat the supply water in vapour which is then jettisoned via fan assisted spouts into the ambient. The Vapac unit is completely controllable via a humidistat which gives the user complete control, set and forget the unit will control itself.

 

                     The Vapac unit is completely controllable via a humidistat which gives the user complete control

Maintenance of server room humidification systems

 

The Vapac replicable cylinder will require changing at least once a year. It is advised to fit a filtration system or inhibitor coil to stop lime scale and debris forming within the cylinder. This will extend the life of the boiling cylinder chamber and save money on maintenance. The Vapac has a intelligent controller which will tell the user when the cylinder needs changing. As you can see with the picture below the container starts to brown.

                   The Vapac replicable cylinder will require changing at least once a year.

Specification of Vapac Humidification Systems:

 
Performance Data
LEP
LE
DV4
Application
Commercial/Industrial
Residential
 
Alphanumeric display
option
no
Voltage/phase
208-600/1 or 3
120-240/1
Capacity lbs/hr (kg/hr)
1-200 (0.5-90)
2-200 (1-90)
6-12 (3-6)
Control type
SSR modulation
on/off or modulating
on/off
Turndown
8-100%
20-100%
n/a
LED status indication
standard
standard
standard
Vapanet Controller
standard
standard
n/a

 