lg air conditioning sales
  Call: +44(0)845 5677080           E-mail: Info@orionair.co.uk

Electrolux Air Conditioning and dehumidifiers

Project featured on BBC TV. Click here to watch

major projects and company news

View gas regulations

View our sales website

Mitsubishi Electric Super High COP Inverter Heat-pump Air Conditioning unit

Portable Server Room Air Conditioning Unit (Heating and Cooling)

Worcester Hot Water Solar Panel Collector Roof Installation Package

Zeus 2.8kw Patio heater with 40w light and magnetic remote control (as seen on Dragons Den)

Mitsubishi SRK20ZIX AIR TO AIR Heat pump with 5.45 C.O.P

Air Conditioning Information

ECA Capital Allowance for business

Air Conditioning installation Manual

Special Offers

Daikin Wall Air Conditioning

Air Source Heat-pump heating systems

Wall Air conditioning

The new Mitsubishi SRF HYPER Inverter Floor Air Conditioning

Ice makers

Self Install / DIY Air Conditioning

Portable Air Conditioning

Conservatory Air Conditioning

 Air conditioning Bedford

Air conditioning Milton-Keynes

Air conditioning Bedfordshire

Air conditioning Luton

Office air conditioning

Air conditioning heating

Solar PV Panels

Wind Turbine

 

Fault Codes For Fujitsu cassette air conditioning

 

Below is the fault / error message that the AUY Cassette air conditioning units display when in error state.

 

Other Fault Codes:
 
Fujitsu Air Conditioning ARYF Floor/Ceiling (concealed) air conditioning Fault Codes
Fujitsu Air conditioning ASYA wall inverter heat pump Fault Codes
Fault Codes for Fujitsu Air Conditioning ASYG-LE/LF Wall Units
Fault Codes for Fujitsu Air Conditioning Cassette Units

 

We can supply spares parts for Fujitsu conditioning equipment please contact below:

Tel: +44(0)845 567 7080

E-mail: info@orionair.co.uk

 

Error code

Error contents

01

Serial

reverse transfer error

13

Serial

forward transfer error

26

Communication error

(

Main PCB

Display PCB

)

27

Communication error

(

Display PCB

Main PCB

)

00

Wired remote controller abnormal

02

Indoor room temperature sensor error

04

Indoor heat exchanger temperature sensor

(middle)

error

28

Indoor heat exchanger temperature sensor

(inlet)

error

09

Float switch operated

0C

Outdoor discharge pipe temperature sensor error

06

Outdoor heat exchanger temperature sensor

(outlet)

error

0A

Outdoor temperature sensor error

15

Compressor temperature sensor error

1d

2-way valve temperature sensor error

1E

3-way valve temperature sensor error

29

Outdoor heat exchanger temperature sensor

(middle)

error

20

Indoor manual

auto switch abnormal

2A

Power supply frequency detection error

17

IPM protection

18

CT error

1A

Compressor

location error

1b

Outdoor fan error

1F

Connected

indoor unit abnormal

1c

Outdoor unit computer communication error

12

Indoor fan abnormal

0F

Discharge temperature error

24

Exessive high pressure protection on cooling

2c

4-way valve abnormal

16

Pressure switch abnormal

2b

Compressor temperature error

19

Active filter abnormal

25

PFC circuit error

Totally silent:  Less time required to reach the temperature, the range of Inverter Fujitsu climate control equipped with DC Inverter I-PAM technology allows to reach the comfort temperature selected a 30% faster than with any other conventional system and in a completely accurate way, with a differential of minimum temperature of only +/- 0.5º The temperature and the air speed are constantly controlled through accurate sensors that avoid sharp variations of temperatures and uncomfortable drafts.

Less consumption: Once the desired temperature is reached, the compressor works under minimum revolutions, far below its nominal capacity. This significantly reduces electricity consumption. The Fujitsu DC Inverter climate controls offers more than 60% of heating capacity than conventional models and can operate under temperature conditions of up to –15º. Maximum heating capacity.

100% Comfort, 0% Noise: When Fujitsu DC Inverter systems reach the temperature you want, the compressor and fan slow down thus reducing the sound enormously. In addition, all fan parts and materials used are designed for maximum quietness.

MODEL

AUY35Ui

AUY40Ui

AUY50Ui

Cooling Capacity

W

3500 (1400-4000)

4000 (1400-4600)

4700 (2000-4900)

Heating capacity

W

4000 (1400-5000)

4600 (1400-5100)

4800 (2000-5200)

Energy Efficiency Ratio (E.E.R.)

Cooling

3.02

2.96

2.85

Heating

2.92

2.82

2.81

Power supply

V/nº/Hz

230/1/50

230/1/50

230/1/50

Power consumption (Cooling/Heating)

kW

1.16/1.37

1.36/1.63

1.65/1.71

Noise level indoor unit

High

db (A)

42

42

44

Medium

db (A)

39

39

41

Low

db (A)

36

36

37

Noise level outdoor unit

db (A)

49

49

50

Dimensions indoor unit

Width

mm

580 (650)

580 (650)

580 (650)

Depth

mm

580 (650)

580 (650)

580 (650)

Height

mm

235 (35)

235 (35)

235 (35)

Minimum height of the false ceiling

mm

250

250

250

Dimensions outdoor unit

Width

mm

830

830

830

Depth

mm

320

320

320

Height

mm

650

650

650

Net weight

Indoor unit

kg

18+2.2

18+2.2

18+2.2

Outdoor unit

kg

54

54

54

Operating range

Cooling

ºC

0 / +43

0 / +43

0 / +43

Heating

ºC

-15 / +24

-15 / +24

-15 / +24

 

MODEL

AUY71Ui

AUY80Ui

AUY100Ui

AUY125Ui

AUY14OUi

Cooling Capacity

W

7100 (2000-8000)

8500 (3000-10000)

10000 (5000-11200)

12500 (3000-14000)

13300 (6400-14500)

Heating capacity

W

7800 (2000-9000)

10000 (3000-11200)

11200 (5600-13200)

14000 (3000-16000)

16000 (6800-16500)

Energy Efficiency Ratio (E.E.R.)

Cooling

2.81

2.70

2.41

2.81

2.44

Heating

3.25

3.64

3.61

3.54

3.23

Power supply

V/nº/Hz

230/1/50

230/1/50

230/1/50

230/1/50

230/1/50

Power consumption (Cooling/Heating)

kW

2.53/2.40

3.15/2.75

4.15/3.10

4.45/3.95

5.45/4.95

Noise level indoor unit

High

db (A)

46

48

48

49

51

Medium

db (A)

44

44

44

47

49

Low

db (A)

39

41

41

43

46

Noise level outdoor unit

db (A)

50

53

53

54

54

Dimensions indoor unit

Width

mm

830 (940)

830 (940)

830 (940)

830 (940)

830 (940)

Depth

mm

830 (940)

830 (940)

830 (940)

830 (940)

830 (940)

Height

mm

246 (130)

296 (30)

296 (30)

296 (30)

296 (30)

Minimum height of the false ceiling

mm

200

250

250

250

250

Dimensions outdoor unit

Width

mm

830

900

900

900

900

Depth

mm

320

330

330

330

330

Height

mm

650

830

830

1290

1290

Net weight

Indoor unit

kg

34

34

34

40

40

Outdoor unit

kg

54

70

70

105

105

Operating range

Cooling

ºC

0 / +43

-10 / +43

-10 / +43

-15 / +43

-15 / +43

Heating

ºC

-15 / +24

-15 / +24

-15 / +24

-15 / +24

-15 / +24

 

 

 

 

 

 

Links:

Tel: +44(0)845 567 7080

E-mail: info@orionair.co.uk


 

 

 

 


Orion Air Conditioning & Refrigeration Ltd, 10 Grisedale Court, Woburn Road Industrial Estate, Kempston, Bedfordshire, MK42 7EE, UK

Terms of Use | Privacy Statement | Accessibility ©2007 Orion AC&R Ltd. All rights reserved