Buy LG air conditioning online-
www.orionairsales.co.uk
Tel: +44 (0)845
5677080
Mail:
info@orionair.co.uk

|
Model |
Indoor Unit Grille |
UT12 NEC PT-HEC |
UT18 NEC PT-HEC |
UT24 NFC PT-HFC |
UT30 NFC PT-HFC |
UT36 NDC PT-HDC |
UT48 NDC PT-HDC |
UT60 NDC PT-HDC |
|
Nominal Capacity Cooling Capacity (UK) Cooling
Nominal Capacity (T1) Heating |
kW |
3.5 |
5.3 |
7 |
8.8 |
10.6 |
14.1 |
15.8 |
|
kW |
3.1 |
4.7 |
6.2 |
7.8 |
9.3 |
12.4 |
14.0 |
|
kW |
4 |
5.8 |
7.7 |
9.7 |
11.6 |
15.5 |
17.4 |
|
Power Supply to Unit |
V/Phase/Hz |
240/1/50 |
240/1/50 |
240/1/50 |
240/1/50 |
415/3/50 |
415/3/50 |
415/3/50 |
|
Power supply to |
|
Outdoor |
Outdoor |
Outdoor |
Outdoor |
Outdoor |
Outdoor |
Outdoor |
|
Inter connecting Cables |
|
4*5A |
4*5A |
4*5A |
4 *5A |
4*5A |
4*5A |
4*5A |
|
cores and rating |
No. Amps |
|
|
|
|
|
|
|
|
Air Circulation Sound Levels Indoor Units Panel
Section Indoor Units |
Indoor |
(m3/min) |
9.5 |
13 |
15 |
19 |
25 |
30 |
34.0 |
|
Indoor |
dB(A)+/-3 (at 1.0m) |
38 |
41 |
43 |
45 |
40 |
43 |
50 |
|
WxHxD |
(mm) |
570 x 269 x 570 |
570 x 269 x 570 |
744 x 292 x 744 |
744 x 292 x 744 |
840 x 288 x 840 |
840 x 288 x 840 |
840 x 288 x 840 |
|
WxHxD |
(mm) |
670 x 30 x 670 |
670 x 30 x 670 |
850 x 30 x 850 |
850 x 30 x 850 |
950 x 30 x 950 |
950 x 30 x 950 |
950 x 30 x 950 |
|
(Kg) |
19 |
19 |
24 |
24 |
32 |
32 |
32 |
|
Liquid |
|
(Inch) |
1/4 |
1/4 |
1/4 |
1/4 |
1/4 |
3/8 |
3/8 |
|
Suction |
|
(Inch) |
3/8 |
1/2 |
1/2 |
5/8 |
5/8 |
3/4 |
3/4 |
|
Drain (ID) |
|
(mm) |
32 |
32 |
32 |
32 |
32 |
32 |
32.0 |
|
T1 Condition: UK Condition: |
Cooling - indoor 27Cwb, 19Cdb; outdoor 35Cdb Heating
- indoor 20Cdb: outdoor 7Cdb, 6Cwb Cooling - indoor 23Cdb, 16Cwb;
outdoor 30Cdb |
Note: Due to our policy of innovation some
specifications may be changed without notification. |
High Ceiling Operation:
Depending on the height of the
installation, LG air conditioners allow you to vary the speed of the
indoor fan motor. When installation is low, the RPM can be
reduced, but it can also be increased when the installation is high to
ensure optimum comfort levels. The speed can be adjusted via the slide
switch on the back of the LCD wired remote.

Ez-Detachable Grille: LG Split Systems are
designed with simple cleaning in mind. The grille is completely
detachable and access is made simple with the upward opening cover
panel. All parts that need to be cleaned can be removed. Now, it
is much easier to clean your air conditioner.
Easy Quick Clean System:
Filters must be kept clean at all times to ensure optimum operation. The
LG Ez-Cleaning Filter is designed for easy handling and cleaning.
Ez-Cleaning Filter:
Moisture in the evaporator can increase the presence of germs and fungi.
The Auto Clean Operation can reduce moisture for a fresh, soft, and dry
condition.
Conventional:
Since the
surrounding temperature is measured after the air from the unit is
widely distributed, an accurate assessment of the air is not possible.
LG Healthy Dehumidification:
By increasing the Vane
Angle, a better assessment of the actual temperature is possible to
prevent over cooling.
Indoor Temperature Distribution Chart:
Optimized Cooling &Heating Air Flow:
The air vanes will be adjusted according
to the mode of operation. In heating mode air will be distributed at a
lower angle due to hot air rising.

|
Model |
Indoor Unit Grille |
UT12 NEC PT-HEC |
UT18 NEC PT-HEC |
UT24 NFC PT-HFC |
UT30 NFC PT-HFC |
UT36 NDC PT-HDC |
UT48 NDC PT-HDC |
UT60 NDC PT-HDC |
|
Nominal Capacity Cooling Capacity (UK) Cooling
Nominal Capacity (T1) Heating |
kW |
3.5 |
5.3 |
7 |
8.8 |
10.6 |
14.1 |
15.8 |
|
kW |
3.1 |
4.7 |
6.2 |
7.8 |
9.3 |
12.4 |
14.0 |
|
kW |
4 |
5.8 |
7.7 |
9.7 |
11.6 |
15.5 |
17.4 |
|
Power Supply to Unit |
V/Phase/Hz |
240/1/50 |
240/1/50 |
240/1/50 |
240/1/50 |
415/3/50 |
415/3/50 |
415/3/50 |
|
Power supply to |
|
Outdoor |
Outdoor |
Outdoor |
Outdoor |
Outdoor |
Outdoor |
Outdoor |
|
Inter connecting Cables |
|
4*5A |
4*5A |
4*5A |
4 *5A |
4*5A |
4*5A |
4*5A |
|
cores and rating |
No. Amps |
|
|
|
|
|
|
|
|
Air Circulation Sound Levels Indoor Units Panel
Section Indoor Units |
Indoor |
(m3/min) |
9.5 |
13 |
15 |
19 |
25 |
30 |
34.0 |
|
Indoor |
dB(A)+/-3 (at 1.0m) |
38 |
41 |
43 |
45 |
40 |
43 |
50 |
|
WxHxD |
(mm) |
570 x 269 x 570 |
570 x 269 x 570 |
744 x 292 x 744 |
744 x 292 x 744 |
840 x 288 x 840 |
840 x 288 x 840 |
840 x 288 x 840 |
|
WxHxD |
(mm) |
670 x 30 x 670 |
670 x 30 x 670 |
850 x 30 x 850 |
850 x 30 x 850 |
950 x 30 x 950 |
950 x 30 x 950 |
950 x 30 x 950 |
|
(Kg) |
19 |
19 |
24 |
24 |
32 |
32 |
32 |
|
Liquid |
|
(Inch) |
1/4 |
1/4 |
1/4 |
1/4 |
1/4 |
3/8 |
3/8 |
|
Suction |
|
(Inch) |
3/8 |
1/2 |
1/2 |
5/8 |
5/8 |
3/4 |
3/4 |
|
Drain (ID) |
|
(mm) |
32 |
32 |
32 |
32 |
32 |
32 |
32.0 |
|
T1 Condition: UK Condition: |
Cooling - indoor 27Cwb, 19Cdb; outdoor 35Cdb Heating
- indoor 20Cdb: outdoor 7Cdb, 6Cwb Cooling - indoor 23Cdb, 16Cwb;
outdoor 30Cdb |
Note: Due to our policy of innovation some